Outdoor | SCM40ZS-W | |||
Power source (Outdoor) | 1 Phase 240V 50Hz | |||
*Operation data |
Nominal Capacity (Range) |
Cooling T1 |
kW |
4.0 (1.5~5.9) |
Heating H1 | 4.5 (1.0~6.3) | |||
Power consumption |
Cooling T1 | 0.80 | ||
Heating H1 | 0.83 | |||
Running current |
Cooling T1 |
A |
3.4 | |
Heating H1 | 3.5 | |||
Inrush current, maximum current | 3.7, 14 | |||
EER | Cooling T1 | 5.00 | ||
COP | Heating H1 | 5.42 | ||
Sound power level (JIS C9612) |
Cooling T1 |
dB(A) |
62 | |
Heating H1 | 64 | |||
Sound pressure level (JIS C9612) |
Cooling T1 | 49 | ||
Heating H1 | 51 | |||
Silent mode |
Cooling T1 | 44 | ||
Heating H1 | 46 | |||
External dimensions (HxWxD) | mm | 595×780(+90)x290 | ||
Net weight |
kg |
40 | ||
Refrigerant (R32) |
Quantity | 1.4 | ||
Pre charged to pipe length | m | 20 | ||
Installation data |
Refrigerant piping |
Liquid line |
mm |
Ø6.35 x 2 |
Gas line | Ø9.52 x 2 | |||
Connection method | Flare connection | |||
Maximum pipe length to one indoor unit |
m |
25 | ||
Total pipe length to all indoor units | 30 | |||
Max vertical height diff. between O.U. and I.U. | 15 ( O.U. above I.U.) / 15 ( O.U. below I.U. ) | |||
Indoor Unit Combination |
SRK-ZSA-W |
kW |
2.0, 2.5, 3.5 | |
SRK-ZSXA-W | 2.0, 2.5, 3.5 | |||
SRK-ZRA-W | ||||
SRF-ZS(X)-W | 2.5, 3.5 | |||
SRR-ZS-W | 2.5, 3.5 | |||
FDTC-VH | 2.5, 3.5 | |||
FDUM-VH | ||||
Indoor Unit Connection | 2 Units | |||
Indoor Connection Capacity | kW | 4.0 to 6.0 | ||
Outdoor air temperature (upper, lower limits) |
Cooling | °C | -15 to 46 | |
Heating | -15 to 24 | |||
* Operation data are are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Page14. | ||||
Warranty
All systems sold by Airconnex have a 5 year manufacturers warranty parts and labour.
For more details refer to each Manufacturers warranty guidelines.