| Outdoor | SCM100ZS-W | |||
| Power source (Outdoor) | 1 Phase 240V 50Hz | |||
|
*Operation data |
Nominal Capacity (Range) |
Cooling T1 |
kW |
10.0 (1.7~11.5) |
| Heating H1 | 10.5 (0.9~11.5) | |||
|
Power consumption |
Cooling T1 | 2.70 | ||
| Heating H1 | 2.38 | |||
|
Running current |
Cooling T1 |
A |
11.4 | |
| Heating H1 | 10.0 | |||
| Inrush current, maximum current | 5, 21 | |||
| EER | Cooling T1 | 3.70 | ||
| COP | Heating H1 | 4.41 | ||
|
Sound power level (JIS C9612) |
Cooling T1 |
dB(A) |
67 | |
| Heating H1 | 72 | |||
|
Sound pressure level (JIS C9612) |
Cooling T1 | 54 | ||
| Heating H1 | 59 | |||
|
Silent mode |
Cooling T1 | 49 | ||
| Heating H1 | 50 | |||
| External dimensions (HxWxD) | mm | 945 x 970 x 370 | ||
| Net weight |
kg |
73 | ||
|
Refrigerant (R32) |
Quantity | 2.98 | ||
| Pre charged to pipe length | m | 40 | ||
|
Installation data |
Refrigerant piping |
Liquid line |
mm |
Ø6.35 x 5 |
| Gas line | Ø9.52 x 5 | |||
| Connection method | Flare connection | |||
| Maximum pipe length to one indoor unit |
m |
25 | ||
| Total pipe length to all indoor units | 75 | |||
| Max vertical height diff. between O.U. and I.U. | 20 ( O.U. above I.U.) / 20 ( O.U. below I.U. ) | |||
|
Indoor Unit Combination |
SRK-ZSA-W |
kW |
2.0, 2.5, 3.5, 5.0 | |
| SRK-ZSXA-W | 2.0, 2.5, 3.5, 5.0, 6.0 | |||
| SRK-ZRA-W | 7.1, 8.0 | |||
| SRF-ZS(X)-W | 2.5, 3.5, 5.0 | |||
| SRR-ZS-W | 2.5, 3.5, 5.0, 6.0 | |||
| FDTC-VH | 2.5, 3.5, 5.0, 6.0 | |||
| FDUM-VH | 5.0 | |||
| Indoor Unit Connection | **3 to 5 Units | |||
| Indoor Connection Capacity | kW | 9.0 to 16.0 | ||
|
Outdoor air temperature (upper, lower limits) |
Cooling | °C | -15 to 46 | |
| Heating | -15 to 24 | |||
Mitsubishi Heavy Industries 10kW Multi Head Outdoor Unit Only SCM100ZS-W
Next Day Delivery
If you checkout before 10am
Flexible Payment Options
Different payment options available
Guarantee Safe Checkout
Mitsubishi Heavy Industries SCM100ZS-W 10kW Multi Split System Outdoor Unit Only
Serves 2 - 4 Indoor Units
Maximum capacity of indoor units allowed: 16kW
Specifications
Warranty
All systems sold by Airconnex have a 5 year manufacturers warranty parts and labour.
For more details refer to each Manufacturers warranty guidelines.