MITSUBISHI ELECTRIC PEAD-M100JAADR1.TH / PUZ-M100VKA-A.TH 10kW Ducted Air Conditioner System 1 Phase

PEAD-M100JAADR1.TH : Indoor – Ducted with Drain Pump
PUZ-M100VKA-A.TH : R32 Inverter Outdoor – Single Phase
PAR-40MAA : Wired Control with Back Light
Low Profile Ducted System Inverter Single Phase
Single Fan Outdoor Unit.

10.0 kW Cooling
11.2 kW Heating

Low Profile Power Inverter

Specifications

Ceiling-Concealed (PEAD-M Series)
Indoor Unit PEAD-M100JAA(D)
Outdoor Unit PUZ-M100VKA
Refrigerant R32
Power Supply V:230V, Single-phase, 50 Hz
Cooling Capacity


[Min-Rated-Max]

(kW) 4.0-10.0-10.6
Total Input [Rated] (kW) 3.06
AEER/EER 3.13 / 3.26
AEER [Part-load %] *1 4.40
Running Current [Rated] A 14.1
Sound


Pressure

Level

In (Lo-Mid-Hi) dB(A) 33-38-42
Out (PWL) 52 (71)
Air Volume (In) Lo-Mid-Hi L/S 400-483-567
Heating Capacity


[Min-Rated-Max]

(kW)


(kW)

2.8-12.5-12.5
Total Input [Rated] 3.35
ACOP/COP 3.59 / 3.73
ACOP Part-load %) *1
Running Current [Rated] (mm) 16.5
Sound


Pressure

Level

In (Lo-Mid-Hi) dB(A) 33-38-42
Out (PWL) dB(A) 54 (72)
Air Volume (In) Lo-Mid-Hi 400-483-567
Max. Running Current A 29.00
Indoor Unit Input [Rated] kW 0.25 / 0.23
Dimensions [HxWxD] mm 250 x 1400 x 732
Weight kg 39
Static Pressure Pa 35 / 50 / 70 / 100 / 125
Outdoor Unit Dimensions [HxWxD] mm 981 x 1050 x 330 (+40)
Weight kg 76
Breaker Size A 32
Ext.


Piping

Diameter [Gas/Liquid] mm 15.88 / 9.52
Max. Length/Height m 55 / 30
Guaranteed


Operating Range [Outdoor]

Cooling *2 °C -5(-15) ~ 46
Heating °C -15 ~ 21
Supply Air Duct mm 1360 x 178
Precharge Refrigerant R32 kg 3.1 (30m)
Additional Refrigerant per


M(g)

200

 

Warranty

All systems sold by Airconnex have a 5 year manufacturers warranty parts and labour.

For more details refer to each Manufacturers warranty guidelines.